| DIGITAL DINRAIL TIMER ---------------------------------------------------------------------------DT25 |
| |
| STANDARD, STAR-DELTA, FORWARD-REVERSE, 9-STEP |
| |
| |
| DT25 : STANDARD TIMER |
| TABLE 1 |
| Range No |
Range |
Resolution |
| 1 |
9.9 s |
0.1 s |
| 2 |
99 s |
1 s |
| 3 |
990 s |
10 s |
| 4 |
9.9 m |
0.1 m |
| 5 |
99 m |
1 m |
| 6 |
990 m |
10 m |
| 7 |
9.9 h |
0.1 h |
| 8 |
99 h |
1 h |
| 9 |
990 h |
10 h |
|
 |
- Universal supply voltage:
20~265 V AC / DC
- 2 digit display
- 0.1 seonds to 990 hours
- 9 user selectable ranges
- 4 user selectable modes
- Incrementing / decrementing display
- ±0.01% quartz crystal acuracy
|
|
 |
|
| |
| SPECIFICATIONS |
| |
| PROGRAMMABLE PARAMETERS |
|
| Range |
See Table 1
Independently selectable for t1 & t2
|
| Setpoints |
t1 & t2 - See Fig 1 |
| Units |
Seconds / Minutes / Hours,
Independently selectable for t1 & t2 |
| Resolution |
See Table 1
Independently selectable for t1 & t2 |
| Control functions |
See Fig 1
ON delay
Interval
C1(Relay ON at power ON)
C2(Relay OFF at power ON) |
| Direction |
UP (Incrementing)
Down (Decrementing)
|
| Program lock |
On, Off |
| ELECTRICAL, MECHANICAL |
|
| Display |
2 digit, 0.39", 7-segment red LED |
| Accuracy |
0.01% of set-time ± 1 display count |
| Time start delay |
0.05 seconds max |
| (after application of power) |
|
| Reset time (minimum) |
50 milliseconds |
| Relay |
Relay 1,1 x NO-C-NC |
| Relay contact rating |
5A/230 V AC, resistive |
| User programming |
2 keys and display |
| Program memory |
Non-volatile |
| Reset |
Front panel key |
|
| Supply voltage |
20~265 V AC/DC |
| Dimensions (in mm) |
80(H) x 25(W) x 85(D) |
| Mounting |
Snap-on for 35 mm DIN rail to DIN 46277 |
| |
| DT25 : 9-STEP TIMER |
SPECIFICATIONS
As for DT25 - Standard Timer except those given below |
| PROGRAMMABLE PARAMETERS |
|
| Start |
P.O (Power on start)
Pb (Push button switch start) |
| Setpoints |
9 |
| ELECTRICAL |
|
| Relay |
Relay 1,1 x NO-C-NC |
|
| |
 |
|
| |
 |
 |
SPECIFICATION
|
SPECIFICATION |
| As for DT25 - Standard Timer except those given below |
As for DT25 - Standard Timer expect those given below |
| PROGRAMMABLE PARAMETERS |
|
| Range |
See Table 2 |
Setpoints
See Fig 3 |
a) Forward setpoint
b) Reverse setpoint
c) Pause setpoint |
| Units |
Seconds / Minutes,
Independent for each setpoint |
| ELECTRICAL |
|
| Relays |
Relay 1,1 x NO-C(Forward)
Relay2, 1 x NO-C(Reverse) |
|
| PROGRAMMABLE PARAMETERS |
|
| Star
setpoint(t2) |
0~99 seconds - See Fig 4 |
| Delta pause setpoint(t1) |
40~99 milliseconds - See Fig 4 |
| ELECTRICAL |
|
| Relays |
Relay 1,1 x NO-C(Star)
|
|
| |
 |
| |
| Table 2 |
| |
| Range |
Unit |
Resolution |
| 9.9 |
S |
0.1 |
| 99 |
S |
1 |
| 990 |
S |
10 |
| 9.9 |
M |
0.1 |
| 99 |
M |
1 |
| 990 |
M |
10 |
|
| |
 |
|
| |
| |
|
|