LOOP POWERED ISOLATOR ---------------------------------------------------------------------------LP2SI |
|
|
|
4~20 mA in, 4~20 mA out
Isolation between input and output :
1.5 KV AC RMS / 1 minute,
250 V AC RMS continuous
0.1% transfer accuracy
5 V loop drop
0~500 Ω load without trimming
DIN rail mounting
No power supply required
|
|
|
|
LP2SI is a loop powered isolator suitable for a variety of applications. It can be used, for example, to isolate the 4~20mA current signal from a 2-wire thermocouple transmitter or temperature controller, and pass it on to a PLC or datalogger. LP2SI eliminates earth and ground loop problems and simplifies interfacing. LP2SI does not require load trimming. Its accuracy is specified for any load between 0 & 500 ohms. |
|
|
SPECIFICATIONS All specifications at ambient of 25 °C, unless specified otherwise. |
|
INPUT |
|
Input current |
4~20 mA DC |
Voltage drop across |
<5 V DC with zero ohms load |
input terminals |
on output |
Reverse polarity |
Provided for current inputs |
Protection |
|
Maximum input current |
50 mA |
OUTPUT |
|
Nominal current transfer |
1:1 in the range of 4~20 mA |
ration |
|
Permissible load |
0~500 ohms without load trim |
resistance |
|
ACCURACY |
|
Linearity & calibration |
<0.1% of span
(I out = I in ± 16 μA) |
Temperature coefficient |
0.01% of span per °C |
of accuracy |
|
|
ISOLATION |
|
Input / Output isolation |
a) 1.5 KV AC RMS, 1 minute
b) 250 V AC RMS, continuous
|
CALIBRATION |
|
Zero, span |
20-turn potentiometers on front face |
ENCLOSURE |
|
Material |
ABS plastic |
Dimensions |
80(H) x 25(W) x 85(D) mm |
Mounting |
snap on for 35 mm DIN rail to DIN 46277 |
Connection, single / |
≤ 2.5 mm2, AWG 14 |
stranded wires |
|
Weight |
<200 grams |
Protection |
IP 20 |
TEMPERATURE, HUMIDITY |
|
Ambient, storage |
-20 to + 85 °C |
Ambient, operation |
-20 to +70 °C |
Relative humidity |
0~95% |
|
|
|
|