2-WIRE TEMPERATURE TRANSMITTER ------------------------------------------------------------------------------------TRX10H
 
INPUT : Pt100 MOUNTING : IN-HEAD
 

  • Solder jumpers for
  • Span
  • Zero
  • Upscale / Downscale
  • 4~20 mA / 20~4 mA
  • Multirange : 8 SPAN range, 25 to 600 C°/45 to 1080 F°
                            4 ZERO ranges, -100 to +70 °C/ -148 to + 158 °F
  • Accurate : 0.1% temperature linear 4~20 mA output
  • 6.5 V loop drop allows 800 Ω load @ 24 V DC
  • Upscale / downscale selectable sensor break detection
  • 4~20 mA or 20~4 mA selection
  • ON LED shows state
  • Pt50, Pt200, Pt500, Pt1000 on request
 
GENERAL

TRX10H is a head mounted high performance, "all-in-one" 2-wire temperature transmitter. Its high reliability industrial design offers some rare functions, e.g. 4~20 mA or 20~4 mA selection.

TRX10H with Pt100 input is adjustable for 8 overlapping ranges in °C or °F and gives a temperature linear output. All selections are made by solder jumpers. 'Fine' ZERO / SPAN potentiometers are provided for calibration.

The flat design gives easy access to terminal & adjustments. The large central hole lets the lead wires or an insert tube pass easily.
 
 

 

Enclosure

 
SPECIFICATIONS          All specifications at ambient of 25° C, unless specified otherwise
 
INPUT  
Input type Pt100 (α = 0.00385), 3-wire connection
Sensor current 0.3 mA
Other input type Pt50, Pt200, Pt500, Pt1000 on request
MONITORING  
Sensoe break detection, Upscale ~25 mA, Downscale ~3 mA
selectable  
ON LED Provided
ADJUSTMENTS  
Zero selection -100 to + 70 °C(-148 to +158 °F) in 4 overlapping ranges (see table below)
Zero, fine adjustment ± 10%
Span selection 25 to 600 C°(45 to 1080F°) 8 Overlapping ranges (See table below)
Span, fine adjustment ± 10%
OUTPUT  
Current, selectable 4~20 mA, 20~4 mA
Linearity Temperature linear
Current limit ~25 mA
Permissible load 800 Ω@ 24 VDC, 22 mA
ACCURACY  
Linearity & calibration ± 0.1% of span
Temperature effect ± 0.5 of span / 25C°
on accuracy ± 0.6% of span / 50 F°
Supply voltage effect ± 0.002% of span / V
POWER SUPPLY  
Supply voltage 6.5 to 32 VDC
ENCLOSURE  
Material Zinc alloy
Mounting DIN B-head or larger
Connection, ≤ 2.5 mm2 , AWG 14
single / stranded wires  
Weight 70 grams
Protection IP 20
TEMPERATURE, HUMIDITY  
Ambient, storage -20 to + 85 °C(-5 to + 185 °F )
Ambient, operation -20 to + 55 °C(-5 to + 160 °F )
Relative humidity 0~95%
 

 
 
 
ZERO, SPAN
Zero selection Span selection
°C °F
-102 to -65 -150 to -85 25 45
-68 to -21 -90 to -5 50 90
-28 to + 29 -18 to +84 100 180
-6 to +73 +21 to +163 200 360
    300 540
    400 720
    500 900
    600 1080
The above zero & span selections are done using solder jumpers. The calibration for a given range is then done using the '4' & '20 mA potentiometers on the instrument front.
 
 
 
 
 
 
 
 
   
 